CONTROL SWITCHES

Control Switch Series · Power-control helpers

Photocell timers, water-loss protectors, time-delay relays and water-heater controllers, made in Taiwan.

Photocell light timer
Industrial grade
Photocell light timer LTP-351

LTP-351

35A high current · light on at dusk, off at dawn, with a settable on-duration

Input voltage
Wide voltage AC110–220V (DC5, 12, 24V, AC277V on request)
Output type
Same as input voltage (dry-contact output on request)
Load capacity
35A
Dimensions
58×60×85 mm
Origin
Taiwan
  • AUTO is the ordinary photocell function: off at dawn, on at dusk, with brightness fine-tuned in Lux.
  • On-duration timing: choose lights on at dusk for 4, 6 or 8 hours and then off automatically; the next dusk they come on again with no resetting, so you don't burn lights for 12 hours from dusk to dawn and you save a lot of electricity.
  • Turns off 1 minute after the surroundings brighten and on 1 minute after they darken (allow for the 1-minute delay when testing).
  • Switch-on level 10–80 Lux; turns off automatically at 5 times the switch-on level or more.
  • Install away from the lamp's own light to avoid false triggering; suitable indoors and outdoors.
LTP-351 wiring diagram
LTP-351 wiring diagram
Water-loss protectors
Industrial grade
Water-loss protectors WS06 / WS08

WS06 / WS08

Cuts power after about 30 seconds without water and restores it automatically when water returns

Pipe size
WS06: 3/4" pipe
WS08: 1" pipe
Maximum flow
20 L/min / 28 L/min
Start-up flow
1.8–2.3 L/min / 4.5–5.5 L/min
Cut-off flow
1.5 L/min / 4 L/min
Input voltage
Wide voltage AC110–220V (DC5, 12, 24V, AC277V on request)
Output type
Power output, same as input voltage (dry contact on request)
Maximum pump
110V: 1 HP 220V: 2 HP
Operating temperature / pressure
0–65°C / 0.03–1.6 MPa
Dimensions
Main unit 58×60×85 mm; sensor 62×30×31 mm
Weight
Main unit 150 g; sensor 40 g
  • No more worry about missed water-outage notices, or a forgotten pump running dry and getting damaged.
  • Simple to install, for indoor and outdoor use; works directly with tap water.
  • If the water carries particles or impurities (for example well water), fit a strainer at the inlet.
  • If the pump power exceeds the maximum rating, add a magnetic contactor.
  • The MS08 is also available, for pipes from 1 inch up to 6 inches.
  • After an outage it powers the pump for 30 seconds every 30 minutes to check whether normal water supply has returned.
WS installation wiring diagram
WS installation wiring diagram
WS installation direction and steps
WS installation direction and steps

Water-Loss Protector FAQ

Why do water pumps often fail when the tap water is cut off?

Because of friction between the supporting and rotating parts inside the pump; with no water to carry the heat away, running dry damages it.

Don't pumps have thermal protection? Why do they still fail?

Thermal protection cuts power only after the pump overheats while running dry, and restores it once it cools. In a long outage it cycles ON-OFF-ON-OFF, so the pump still runs dry for a considerable time, shortening its life.

How can I prevent pump failure during a long water outage?

Add a water-loss protector (flow switch). It decides by whether water is present, so a long outage does not cause repeated dry running. About 30 seconds without water, the flow switch cuts power; when water returns, power is restored automatically and the pump runs again.

Time-Delay Relay Switch
Industrial grade
Time-Delay Relay Switch DS-30 / DP-30

DS-30 / DP-30

Switches off automatically after a set time once triggered · controls up to 30A with a small signal

Input voltage
Wide voltage AC110–220V (DC5, 12, 24V, AC277V on request)
Output type
DS: dry contact; DP: same as input voltage (wet contact)
Load capacity
30A
Dimensions
103×56×34 mm
Delay time
15M, 120M (adjustable up to 15 or 120 minutes)
  • A trigger on SW turns the output on and it switches off after the timer ends; triggering again within the time restarts the timer.
  • Controls fans, water heaters, motors and other loads, or lighting circuits.
  • Lower cost than an SSR plus power supply, with no heat-dissipation problem.
  • Do not interconnect the control lines of different units; voltage, time and operating mode can be customized.
DS-30 wiring diagram (dry-contact output)
DS-30 wiring diagram (dry-contact output)
DP-30 wiring diagram (mains output)
DP-30 wiring diagram (mains output)
Water-heater controller
Industrial grade
Water-heater controller HTP-35

HTP-35

Start with a button and switch off on a timer, so you never forget to turn off the water heater

Input voltage
Wide voltage AC110–220V
Input type
Same as supply voltage
Load capacity
35A
Dimensions
Controller 58×60×85 mm; panel 120×70×50 mm
Timing
5 seconds (for testing), 30 min, 1 hour, 2 hours
  • For water heaters, lighting, ventilation equipment and other appliances that need timing.
  • Example: press the button when you start a shower; the water heater starts and switches off by itself after 30 minutes, so it does not heat all day and uses power only when needed.
  • The panel looks neat, the push button is waterproof and the indicator is low-voltage, so it is safe against leakage; the indicator lights while the appliance is running.
  • One to three push buttons can be wired in parallel, so panels can be fitted in different shower rooms to control the same water heater.
  • Use thick wire (35A) for the black, red and white wires, and thin wire (0.5A) for the control wires between the controller and panel, matched by color.
HTP-35 wiring diagram
HTP-35 wiring diagram