High-current timers use high-grade flame-retardant components and need no external magnetic contactor within the rated current, up to 35A. The TP and DTP series are made in Taiwan.

Standard
Industrial grade
Timer TP-351 / TS-351 (Standard)

TP-351 / TS-351

Signboards, electric water heaters, aquaculture, lighting, and any appliance that needs timed operation

Input voltage
Wide voltage AC110–220V (DC5V, 12V, 24V, AC277V available on request)
Output type
Same as input voltage (dry contact / A contact available on request)
Resistive load (electric water heaters)
AC110V / 35A, AC220V / 35A (suitable for AC220V 6KW water heaters)
Lamps (fluorescent, LED)
AC110V/18A, AC220V/15A
Motors (COSφ ≥ 0.7)
AC110V/1200W (1HP), AC220V/2400W (2HP)
Minimum interval
15 min per segment (per tab)
Maximum operations
96 per day
Power-failure backup
Mechanical: 10 days
Dimensions
L150 × W100 × H50 mm
  • Mechanical operation, simple setup.
  • Power-failure backup: no need to reset after a short outage.
  • Flame-retardant engineering plastic, safe and durable.
  • No magnetic contactor needed within the rated current, for easy installation (up to 35A).
Manual-override type
Industrial grade
Timer TP-351EX (Manual-override type)

TP-351EX

Includes standard timing, plus a manual-override function

Input voltage
Wide voltage AC110–220V (DC5V, 12V, 24V, AC277V available on request)
Output type
Same as input voltage (dry contact / A contact available on request)
Resistive load (electric water heaters)
AC110V / 35A, AC220V / 35A (suitable for AC220V 6KW water heaters)
Lamps (fluorescent, LED)
AC110V/18A, AC220V/15A
Motors (COSφ ≥ 0.7)
AC110V/1200W (1HP), AC220V/2400W (2HP)
Minimum interval
15 min per segment (per tab)
Maximum operations
96 per day
Power-failure backup
Mechanical: 10 days
Dimensions
L150 × W100 × H50 mm
  • For water heaters, underground car-park exhaust fans and other appliances that sometimes need to be started on demand.
  • Outside the programmed ON times, press the red button once to start the appliance without changing the schedule; it switches off automatically after 0–120 minutes (adjustable), so you cannot forget to reset it.
Rain-sensing type
Industrial grade
Timer TP-351W (Rain-sensing type)

TP-351W

Rain-sensing timer · developed for professional agriculture

Input voltage
Wide voltage AC110–220V (DC5V, 12V, 24V, AC277V available on request)
Output type
Same as input voltage (dry contact / A contact available on request)
Resistive load (electric water heaters)
AC110V / 35A, AC220V / 35A (suitable for AC220V 6KW water heaters)
Lamps (fluorescent, LED)
AC110V/18A, AC220V/15A
Motors (COSφ ≥ 0.7)
AC110V/1200W (1HP), AC220V/2400W (2HP)
Minimum interval
15 min per segment (per tab)
Maximum operations
96 per day
Power-failure backup
Mechanical: 10 days
Dimensions
L150 × W100 × H50 mm
  • Simple to operate and saves electricity; the pump does not run in the rain, so there are no wasted trips to the field.
  • In fine weather it runs on the clock schedule; when the sensor detects rain the timer stops its output, and it resumes automatic operation once the rain stops.

TP / TS series wiring diagrams

Wiring is the same as the DTP / DTS: the TP has power output (same as the DTP diagram) and the TS has dry A-contact output (same as the DTS diagram). Click a diagram to enlarge.

TP series wiring diagram (same as DTP)
TP series wiring diagram (same as DTP)
TS series wiring diagram (same as DTS, dry A contact)
TS series wiring diagram (same as DTS, dry A contact)
Digital
Industrial grade
Timer DTP-357 / DTS-357 (Digital)

DTP-357 / DTS-357

16 on/off programs · weekly schedule · 60-day power-failure backup

Input voltage
Wide voltage AC110–220V (DC5V, 12V, 24V, AC277V available on request)
Output type
Same as input voltage (dry contact / A contact available on request)
Resistive load (electric water heaters)
AC110V / 35A, AC220V / 35A (suitable for AC220V 6KW water heaters)
Lamps (fluorescent, LED)
AC110V/18A, AC220V/15A
Motors (COSφ ≥ 0.7)
AC110V/1200W (1HP), AC220V/2400W (2HP)
Timing range
1 minute – 168 hours
Programs
16 (on/off) per week
Power-failure backup
Digital: 60 days
Size / weight
L150 × W100 × H50 mm / 370 g
Output
DTP: power output; DTS: dry A contact
Origin / manufacturer
Taiwan / JETWELL TECHNOLOGY CO., LTD.
  • Never overload; doing so is dangerous.
  • Do not overlap the set times of different programs, to avoid erroneous operation.

DTP-357 / DTS-357 operating instructions

Setting the current time

Hold the "Clock" key and press "Week", "Hour" and "Minute" to adjust.

Setting the timer

Press "Timer" once; the screen shows "1 ON", the switch-on time of program 1. Adjust with "Week", "Hour" and "Minute". Press "Timer" again to show "1 OFF", the switch-off time. Keep pressing "Timer" to set programs 2–16 in turn.

Cancelling a program

When the ON/OFF of program N is not needed, press "Clear/Recall"; the screen shows "--:--" to indicate it is cancelled and that program will not switch on.

Setting the weekdays

"Week" offers 15 weekday combinations (MO TU WE TH FR SA SU).

Manual mode

MANUAL: ON / AUTO / OFF.

DTP-357 wiring diagram
DTP-357 wiring diagram
DTP-357 panel keys
DTP-357 panel keys
DTS-357 wiring diagram (dry contact)
DTS-357 wiring diagram (dry contact)
Rain-proof · wall-mount
Economy
Timer TB388-R (Rain-proof · wall-mount)

TB388-R

IP53 rain-proof, wall or surface mounting

Protection rating
IP53
Dimensions
160×113×45 mm
Weight
270 g
Installation
Wall or surface mounting
Input voltage
AC110–220V wide voltage
Load
Resistive load 20A / inductive load 16A
Minimum interval / operations
15 min per segment · 96 per day
Power-failure backup
About 3 days
  • The TB series is not suitable for electric water heaters or LED fixtures.
  • The TB series is made in mainland China.
Metal case · wall-mount
Economy
Timer TB-383 (Metal case · wall-mount)

TB-383

Metal case, wall or surface mounting

Housing
Metal case
Dimensions
150×106×50 mm
Weight
480 g
Installation
Wall or surface mounting
Input voltage
AC110–220V wide voltage
Load
Resistive load 20A / inductive load 16A
Minimum interval / operations
15 min per segment · 96 per day
Power-failure backup
About 3 days
  • The TB series is not suitable for electric water heaters or LED fixtures.
  • The TB series is made in mainland China.
DIN-rail type
Economy
Timer TB-38N (DIN-rail type)

TB-38N

DIN-rail or surface mounting, smaller size (fits IEC 35 mm DIN rail)

Housing
DIN-rail type
Dimensions
110×72×45 mm
Weight
250 g
Installation
IEC 35 mm DIN rail or surface mounting
Input voltage
AC110–220V wide voltage
Load
Resistive load 20A / inductive load 16A
Minimum interval / operations
15 min per segment · 96 per day
Power-failure backup
About 3 days
  • The TB series is not suitable for electric water heaters or LED fixtures.
  • The TB series is made in mainland China.