JETWELL Technology Request a quote 中文
INFRARED (PIR) CEILING SENSOR

PIR Automatic Motion-Sensing Switches

The whole range works with all kinds of lamps (including electronic ballasts and LEDs) and automates lighting in corridors, garages, bathrooms, elevators and more. All models made in Taiwan.

Wall-mounted · Indoor
Economy
PIR motion-sensor switch RP-201 (Wall-mounted · Indoor)

RP-201

For a single lamp · one indoor sensing area

Input / output
AC100–220V / AC100–220V
Load
Single lamp
Detection angle
145°
Detection range
8–10 m
Sensitivity
Automatic
Dimensions
71×46×55 mm
  • One indoor sensing area, not waterproof; choose the 601 series if you need water resistance.
  • On-time (5 s – 15 min) and light-sensing level are adjustable.
RP-201 detection range (3M / 7M)
RP-201 detection range (3M / 7M)
Moisture-resistant
High-current Pro
PIR motion-sensor switch RP-601 / RS-601 (Moisture-resistant)

RP-601 / RS-601

For multiple lamps · bathrooms, arcades

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Dimensions
74×46×55 mm
  • For bathrooms, under outdoor eaves and rain-splashed arcades; one sensing area; do not submerge.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
Recessed · spring mount
High-current Pro
PIR motion-sensor switch RP-701 / RS-701 (Recessed · spring mount)PIR motion-sensor switch RP-701 / RS-701 (Recessed · spring mount)

RP-701 / RS-701

For multiple lamps · recessed-light holes

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Dimensions
100×100×31 mm
Cut-out
Diameter 80 mm
  • Indoor, senses downward; one sensing area.
  • For recessed mounting, cut an 80 mm round hole.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
RP / RS-701 detection range (horizontal)
RP / RS-701 detection range (horizontal)
Indoor ceiling-mount
High-current Pro
PIR motion-sensor switch RP-301 / RS-301 (Indoor ceiling-mount)PIR motion-sensor switch RP-301 / RS-301 (Indoor ceiling-mount)

RP-301 / RS-301

For multiple lamps · senses downward

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Dimensions
100×100×56 mm
  • Indoor, senses downward; one sensing area.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
RP / RS-301 detection range (horizontal)
RP / RS-301 detection range (horizontal)
Extended (dual-eye) · Indoor
High-current Pro
PIR motion-sensor switch RP-301D / RS-301D (Extended (dual-eye) · Indoor)PIR motion-sensor switch RP-301D / RS-301D (Extended (dual-eye) · Indoor)

RP-301D / RS-301D

Indoor areas in different directions or around corners

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Extension cable length
5 m / 10 m / 20 m optional
Main unit size
Same as 301 series
  • Please check the extension cable length when ordering.
  • The photo shows one large and one small sensor; you can ask for two large ones when ordering.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
Waterproof extended (dual-eye) · Outdoor
High-current Pro
PIR motion-sensor switch RP-601D / RS-601D (Waterproof extended (dual-eye) · Outdoor)PIR motion-sensor switch RP-601D / RS-601D (Waterproof extended (dual-eye) · Outdoor)

RP-601D / RS-601D

Bathrooms, arcades, stairs, elevator entrances, corridors

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Extension cable length
5 m / 10 m / 20 m optional
Main unit size
Same as 601 series
  • Suited to sensing areas in different directions or around corners.
  • The photo shows one large and one small sensor; you can ask for two large ones when ordering.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
Recessed extended (dual-eye)
High-current Pro
PIR motion-sensor switch RP-701D / RS-701D (Recessed extended (dual-eye))PIR motion-sensor switch RP-701D / RS-701D (Recessed extended (dual-eye))

RP-701D / RS-701D

Arcades, stairs, elevator entrances, corridor corners

Input voltage
Wide voltage AC110–220V
Load
LED fixtures up to 500W
or 10 low-power units
Angle / range
145° / 8–10 m
Sensitivity
Automatic
Output
RP: same as input voltage
RS: C contact (dry contact)
Extension cable length
5 m / 10 m / 20 m optional
Cut-out
Diameter 80 mm
  • For recessed mounting, cut an 80 mm round hole.
  • The photo shows one large and one small sensor; you can ask for two large ones when ordering.
  • On-time (5 s – 15 min) and light-sensing level are adjustable; other voltages (DC5V, 12V, 24V, AC277V) available on request.
RP / RS-701D detection range (horizontal)
RP / RS-701D detection range (horizontal)
Socket adapter · bulb holder
Economy
PIR motion-sensor switch JRC-501 (Socket adapter · bulb holder)

JRC-501

Automates bulb lighting with no wiring — fully DIY (works with any bulb type, including energy-saving bulbs)

Input voltage
AC100V–AC230V
Load
60W
Detection angle
360° all-round
Delay time
2 s – 5 min
Product size
70×126 mm
Suitable for
Single lamp
  • Day / night operation can be set by the user.
  • Installation is complete once fitted in the lamp holder.
JRC-501 detection range (2M / 3M / 3.8M / 5.6M / 7.6M)
JRC-501 detection range (2M / 3M / 3.8M / 5.6M / 7.6M)

Microwave or PIR — how to choose?

Either works in most situations; consider these cases first:

Choose PIR
  • Small area, and you don't want movement through walls to trigger it
  • A narrower detection angle is needed
  • Elevators, pipes etc. nearby
Choose microwave
  • Large area
  • Sensor hidden in a light-steel ceiling frame or inside a fixture
  • Hot, stuffy places such as basements
See the MP-600 Microwave Sensor →
WIRING

RP / RS wiring

Wire in series with the live line, or cut the neutral line, as needed

RP series (power output)

R stands for infrared and P for POWER output, so it can drive a lamp directly. Example: the RP-601 outputs AC110V on AC110V input and AC220V on AC220V input; the RP-612 outputs AC/DC 12V on AC/DC 12V input.

With the wall switch ON, the lamp follows the sensor (AUTO); with it OFF, the lamp is off.

RS series (dry-contact output)

S stands for a switch output (pure dry contact, no power supplied); the RS-601 provides one independent circuit with a C-contact switch.

With the wall switch ON, the lamp stays on; with it OFF, the lamp follows the sensor (AUTO).

Wiring diagram: RP, MP series (left) / RS, MS series (right)
Wiring diagram: RP, MP series (left) / RS, MS series (right)

Load current below 5A (RP / RS); for loads above 5A, use together with the PS-35 or PP-35.

INSTALL

Installation direction and precautions

Sensitivity is highest when people or objects pass across the sensor from the side

Animation: a person walks across the sensing area from the side and the light comes on; it turns off after a delay once they leave.

Sensitivity is better when people or objects move across the sensor (correct) and poorer when they approach head-on (incorrect). Choose the mounting direction using the detection-range diagram.

Precautions

  • Do not point the sensor at a lamp that is hot at close range.
  • Do not let the sensor be splashed or submerged; it withstands up to 85% humidity.
  • Observe the maximum load on the label: resistive loads, lamps and heating wire can use the full wattage, while inductive loads such as motors and fluorescent lamps are limited to 60% of the resistive rating.
  • Avoid places where temperature changes by 3°C/s or more (air-conditioning outlets, fans blowing directly, outdoor balconies, etc.).
  • Cats and dogs can also trigger the sensor; adjust the sensor angle yourself if needed.
  • To reduce the sensing area, cover part of the sensing head (white plastic dome) with black tape.
  • RP / MP wiring: black = input (live), white = neutral, red = output (live). RS series: blue = COM (common), yellow = N.O. (normally open), green = N.C. (normally closed).

RP / RS maximum load

ModelInput voltageOutput typeResistive load (ordinary incandescent lamps)Lamp load (LED, fluorescent)
RP-601AC100V–220V auto-switchingAC100V–220V, same as input voltage8A (AC110V/800W, AC220V/1500W)6A (10 LED fixtures or up to 500W)
RP-612AC/DC 12V auto-switchingAC/DC 12V, same as input voltage
RS-601AC100V–220VC contact5A3.5A
RS-612AC/DC 12V

For loads above 5A, use together with the PS-35 or PP-35. Made in Taiwan.

FAQ

When does a PIR motion sensor operate?

A PIR sensor only receives changes in body heat and emits nothing, so there is no electromagnetic-wave concern. It is designed to act only when there is a temperature difference of 3°C/s or more and there is "movement"; it will not act if someone is present but still.

What are the TIME and LIGHT adjustments?

TIME: how long the light stays on after people leave. For example, about 5 minutes at the 1/3 position; if someone enters again at 4 min 30 s, TIME restarts automatically. We recommend 3–5 minutes, and 10 minutes or more for bathrooms.
LIGHT: the day ☼ setting works around the clock, day or night, lighting whenever someone enters (e.g. bathroom equipment); the night ☾ setting acts only at night when someone enters and does not sense in daylight. Avoid the middle positions, as ambient brightness varies with the seasons.

What is the difference between indoor and outdoor models?

Indoor models must be installed where they never get rained on; outdoor models (moisture-resistant / waterproof extended) can be installed in arcades and places that get rain, but must not be submerged.

Where can the extended dual-eye models be used?

When there are two entrances or two corner entrances but only one lamp, a dual-eye or extended dual-eye model lights the lamp whenever either sensor detects someone.

What is automatic sensitivity adjustment?

PIR sensing relies on the difference between ambient and body temperature: the difference is smaller in summer (lower sensitivity) and larger in winter (higher sensitivity). To keep the detection range consistent, all our PIR sensors have automatic compensation built in.

Related products